MCS180x Linear Hall-Effect Current Sensors

Monolithic Power Systems (MPS) MCS180x Linear Hall-Effect Current Sensors feature a small footprint that saves board space and is well-suited for space-constrained applications. The series is offered in SOIC-8 packaging with a tape-and-reel option. The MCS180x modules are used for AC and DC current sensing. The Hall array is differential, which cancels out the stray magnetic field. These sensors provide two power supply options (3.3V or 5V) and a wide current range for the best accuracy in different applications. Other features include adjustable bandwidth up to 100kHz, 4μs output rising time, and -40°C to +125°C operating temperature range. Typical applications for MPS MCS180x Linear Hall-Effect Current Sensors include motor controls, automotive systems, load detection and management, switch-mode power supplies, and overcurrent fault protection.

Ergebnisse: 31
Auswählen Bild Teile-Nr. Herst. Beschreibung Datenblatt Verfügbarkeit Preis (CHF) Ergebnisse in der Tabelle nach dem Einheitspreis bei Ihrer Menge filtern. Menge RoHS ECAD Model Nennstrom Art des Sensors Ansprechzeit Präzision Frequenzbereich Betriebsversorgungsspannung Art der Ausgabe
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1
Rolle: 2'500

50 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1
Rolle: 2'500

10 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1
Rolle: 2'500

20 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1
Rolle: 2'500

10.5 mA Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1
Rolle: 2'500

40 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 2'500
Mult.: 2'500
Rolle: 2'500

50 A Current Sense 5 us 5 V Analog