MCQ1805 Hall-Effect Current Sensors

Monolithic Power Systems (MPS) MCQ1805 Hall-Effect Current Sensors are AEC-Q100 automotive-grade sensors designed for AC or DC current sensing. The MCQ1805 sensors' differential Hall array cancels stray magnetic fields, while a low-resistance primary conductor directs current near the IC. The current generates a magnetic field detected at two points by Hall-effect transducers. The difference in the magnetic field is converted into a voltage proportional to the current, and a spinning current technique ensures a low and stable offset. The MCQ1805 current sensors offer fast Over-Current Detection (OCD) to monitor the system for Over-Current (OC) faults. Typical applications include automotive systems, motor controls, Switch-Mode Power Supply (SMPS), and Over-Current (OC) fault protection.

Ergebnisse: 6
Auswählen Bild Teile-Nr. Herst. Beschreibung Datenblatt Verfügbarkeit Preis (CHF) Ergebnisse in der Tabelle nach dem Einheitspreis bei Ihrer Menge filtern. Menge RoHS ECAD Model Nennstrom Art des Sensors Ansprechzeit Präzision Betriebsversorgungsspannung Art der Ausgabe
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3kVRMS Isolated Hall-Effect Current Sensor with 580VRMS Working Voltage and Over-Current Detection, AEC-Q100 Qualified 494Auf Lager
Min.: 1
Mult.: 1
10 A Current Sense 4 us 2.5 % 3.3 V Ratiometric
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3kVRMS Isolated Hall-Effect Current Sensor with 580VRMS Working Voltage and Over-Current Detection, AEC-Q100 Qualified 500Auf Lager
Min.: 1
Mult.: 1
5 A Current Sense 4 us 2.5 % 5 V Ratiometric
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3kVRMS Isolated Hall-Effect Current Sensor with 580VRMS Working Voltage and Over-Current Detection, AEC-Q100 Qualified 500Auf Lager
Min.: 1
Mult.: 1
50 A Current Sense 4 us 2.5 % 5 V Ratiometric
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3kVRMS Isolated Hall-Effect Current Sensor with 580VRMS Working Voltage and Over-Current Detection, AEC-Q100 Qualified Nicht-auf-Lager-Vorlaufzeit 22 Wochen
Min.: 2'500
Mult.: 2'500
10 A Current Sense 4 us 2.5 % 3.3 V Ratiometric
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3kVRMS Isolated Hall-Effect Current Sensor with 580VRMS Working Voltage and Over-Current Detection, AEC-Q100 Qualified Nicht-auf-Lager-Vorlaufzeit 22 Wochen
Min.: 2'500
Mult.: 2'500
5 A Current Sense 4 us 2.5 % 5 V Ratiometric
Monolithic Power Systems (MPS) Stromsensoren für Plattenmontage 3kVRMS Isolated Hall-Effect Current Sensor with 580VRMS Working Voltage and Over-Current Detection, AEC-Q100 Qualified Nicht-auf-Lager-Vorlaufzeit 22 Wochen
Min.: 2'500
Mult.: 2'500
50 A Current Sense 4 us 2.5 % 5 V Ratiometric